Skip to content
Amptech Pty Ltd — calibration services Perth
Process calibrator calibration · Mining

Process calibrator calibration for mining

Processing plants run on 4–20 mA loops, and the instrument technicians who maintain them carry a process calibrator as their reference. If it is out, every loop check since its last calibration is in question — which is why plant instrumentation teams keep these on a strict recall.

A process calibrator is the reference your instrument technicians carry to the plant, so an error in it is copied into every transmitter and loop they check. AmpTech calibrates loop and multifunction process calibrators in our Caversham lab on both their source and measure functions, against references traceable to national standards.

Interval in mining

12 months

Reference instrument for plant loop checks

Setting the interval

Twelve months is standard for process calibrators. Because every reading the instrument gives becomes someone else's calibration record, plant-instrumentation teams tend to hold this interval firmly rather than extend it.

What the calibration covers

  • mA source and measure at points across the 4–20 mA span and beyond
  • Voltage source and measure on each range
  • Thermocouple simulation and measurement for each type the instrument supports, including cold-junction compensation
  • RTD simulation and measurement at resistance values across the range
  • Frequency and pulse functions where fitted
  • Loop power supply output where the instrument provides it

What your certificate records

The certificate format mining procurement and audit teams ask for: the equipment under test, its serial number, the reference instruments used, as-found and as-left readings, environmental conditions and a traceability statement, plus the process calibrator-specific items below.

  • As-found and as-left results for each source and measure function tested
  • Thermocouple and RTD simulation results by type and test point
  • Reference standards used, with their traceability
  • Environmental conditions at the time of calibration

Standards & frameworks in mining

  • ISO 9001 quality management system
  • AS/NZS 3760 for portable electrical equipment on site
  • WHS (Mines) Regulations 2022 (Western Australia)
  • Operator-specific prequalification requirements

How mining clients get process and loop calibrators to us

Calibration is performed in our Caversham lab — not on site. We collect from and deliver back to mining workshops and offices across Perth, and instruments from regional sites come by freight or via your Perth base.

  • Mining head offices in Perth CBD and West Perth
  • Welshpool / Kewdale freight and equipment hubs supporting Pilbara operations
  • Malaga and Bayswater workshops fitting out mine vehicles and tooling
  • FIFO bases at Perth Airport — fast-turn calibration before flights out

Working with mining procurement

We work with mining procurement teams on POs, prequalification packs and instrument-by-instrument quotes. Every calibration ships with a clear certificate showing as-found / as-left readings and a traceability statement — exactly what auditors and PMC reviews ask to see.

FAQ

Process calibrator calibration for mining FAQs

We have several calibrators across different sites — can you stagger them?
Yes. Send them in a batch or one at a time — we log each unit separately with its own due date and remind you before each falls due, so you never have all of them off site at once.
Do you calibrate both the source and measure sides?
Yes. Source functions are measured against our reference meters, and measure functions are fed known values from our reference sources, so both halves of the instrument are covered on the certificate.
Which thermocouple types do you cover?
The common industrial types the instrument supports — typically K, J, T, E, N, R and S — are simulated and measured at points across the range. Tell us which types you actually use and we will make sure they are on the certificate.

Get a process calibrator calibration quote for mining

Send us your equipment list for a fast, no-obligation quote — or call and speak to a calibration technician today.