Thermocouple calibration for manufacturing
Ovens, kilns, cookers and curing lines on Perth production floors are controlled by thermocouples and RTDs, and the product record depends on them. Calibrating the sensor with its indicator is what makes the temperature in the batch record defensible.
Thermocouples and RTDs are the sensors behind process control, ovens and test rigs, and their errors are invisible until something is checked against a reference. AmpTech calibrates thermocouple and RTD sensors in our Caversham lab against a reference thermometer traceable to national standards, either as a sensor alone or as a sensor-and-indicator system.
Interval in manufacturing
12 months
ISO 9001; process control records
Setting the interval
Twelve months is standard. Thermocouples that run hot age quickly and are often treated as consumables on a shorter interval; RTDs are more stable but suffer from lead and connection problems.
What the calibration covers
- Sensor output against a reference thermometer at points between −25 °C and +140 °C
- System calibration — sensor plus indicator read together, where you send both
- Indicator accuracy alone, using simulated inputs, where the sensor is fixed in plant
- Lead and connector condition, which affects thermocouple readings
What your certificate records
The certificate format manufacturing procurement and audit teams ask for: the equipment under test, its serial number, the reference instruments used, as-found and as-left readings, environmental conditions and a traceability statement, plus the thermocouple & rtd-specific items below.
- As-found and as-left readings at each temperature point
- Whether calibrated as a sensor alone or as a sensor-and-indicator system
- Reference thermometer and equipment used, with traceability
- Environmental conditions at the time of calibration
Standards & frameworks in manufacturing
- ISO 9001 quality management system
- ISO 10012 (referenced) — measurement management
- AS/NZS 3760 for portable electrical equipment on plant
- Customer-specific PPAP / quality requirements
How manufacturing clients get thermocouples and RTDs to us
Calibration is performed in our Caversham lab — not on site. We collect from and deliver back to manufacturing workshops and offices across Perth, and instruments from regional sites come by freight or via your Perth base.
- Canning Vale and Bibra Lake manufacturing precincts
- Welshpool and Kewdale fabrication and assembly workshops
- Malaga light industrial and trade workshops
- Osborne Park commercial and QC laboratories
Working with manufacturing procurement
We work with quality and production teams to align calibration intervals with your control plan, supply certificates that map directly to your gauge register, and schedule recall reminders so nothing falls out of cal during a production run.
Thermocouple & RTD calibration for manufacturing FAQs
We have sensors fixed inside plant — what can you calibrate?
Should I send the indicator with the thermocouple?
What temperature range can you cover?
Related pages
Get a thermocouple & rtd calibration quote for manufacturing
Send us your equipment list for a fast, no-obligation quote — or call and speak to a calibration technician today.